M5x.5 Tapped Hole |
These instructions are intended to create a New Standard for additional tapped holes or other features in the SolidWorks Hole Wizard and Toolbox. The following instructions show the steps for adding a Metric Fine Tapped Hole Standard. These Metric Fine Threads can be found on Festo Sensors for example.
STEP 1
On the Menu Bar (Standard Toolbar), Select Options → System Options → Hole Wizard/Toolbox → Configure…then the Toolbox Configure Window will appear.
This method is shown below (a second method is from the SolidWorks Menu, Select Tools → Options → System Options → Hole Wizard/Toolbox → Configure… then the Toolbox Configure Window will appear).
If this is your first time setting up the Hole Wizard/Toolbox. This is the point where you can Uncheck/Turn Off the Toolbox Standards that you Will Not Use. The reason for unchecking/turning off these Standards is so the Hole Wizard Drop-Down Menu will only contain the items that you use.
Select the “Copy Standards” icon.
The Enter New Standard Name Box will appear. Type in the New Name you wish to call this New Standard, we will be using the name “Metric Fine Threads”. You will notice that SolidWorks is creating a New Standard once the Green Check is selected.
The Contents of the Metric Fine Threads will appear. Uncheck/Turn Off everything that you Do Not want to show. You can always go back and Check/Turn On the items you want to show in the future. In this instruction, we will Uncheck/Turn Off everything except for the Hole Wizard Holes folder. Then Select the Hole Wizard Folder.
The result will be 3 folders appearing on the screen, Bottoming Tapped Holes, Straight Pipe Tapped Holes, and Tapped Hole icons. Here we will Uncheck/Turn Off the Bottoming Tapped Holes and Straight Pipe Tapped Holes icons because we creating Tapped Holes.
The Customize Hardware window will then appear.
Type in the requested information, we add Size M5x.5, Pitch .5, and Diameter 5 for our M5x.5 Tapped Hole. Then Select the OK Button located at the Bottom Left Corner.
The Toolbox Additional Information Window will appear, just Select Ok.
Select the “Add New Row” icon, located next Enabled.
Some of the Information Names are not clear thus, below is an explanation what they mean. In the bracket is the information used for our thread. The information used in this instruction can be found in the Machinery’s Handbook.
Advance: Thread Pitch (.5)
Thread Minor Thread: Minor Diameter of an External Thread (4.272)
Thread Minor Thread Inside: Minor Diameter of an Internal Thread (4.599)
Fullsize: Hole Callout Display (M5x.5)
Then Select the Hole Wizard and Select Standard → Metric Fine Threads, Type → Tapped Holes, and Size → M5x.5. Select the Green Check Button.
Now create a Drawing to check if the Tapped Hole Callout is correct.
Congratulations, you have created a new Hole Wizard/Toolbox Standard.
Article by Ralph Wright, CSWP
Menu Bar (Standard Toolbar) Method |
STEP 2
Toolbox Setup Window |
Pick “1. Select your Hardware” from the Toolbox Setup Configure List.
Toolbox Standards Window |
The Toolbox Standards Window will appear.
STEP 3
Uncheck/Turn Off Toolbox Standards Not Used |
ANSI Metric Standard – American |
STEP 4
Select the Standard that you wish to copy, for this example we will copying the American “ANSI Metric” Standard. Once selected the contents of the ANSI Metric Standard will appear. Also shown are the icons for Backup and Copy Standards.Copy Standard Icon |
Select the “Copy Standards” icon.
STEP 5
Enter New Standard Name Box |
STEP 6
Once the New Standard is created, you will now notice it on your main screen with the rest of your Standards. You will notice a Folder with a Red Cross; this is to Delete a Standard. If you want to remove a Standard in the future this is where you go to remove the Standard. Select the Metric Fine Thread located in the Left Panel.
New Metric Fine Threads Standard Created |
STEP 7
Uncheck/Turn Off Items Not Required |
Uncheck/Turn Off Straight Holes Folder |
STEP 8
The contents will appear on the screen, Straight Holes and Tapped Holes folders. Uncheck/Turn Off the Straight Holes folder as we will be creating Tapped Holes. Select the Tapped Holes Folder.
STEP 9
Uncheck/Turn Off Bottoming Tapped Holes and Straight Pipe Tapped Holes Icons |
STEP 10
Now Select Option #2 on the Top Toolbar on your screen, located to the right of Select Hardware.Select the Option #2 on the Top of Toolbar |
The Customize Hardware window will then appear.
Select the Newly Created Standard, Metric Fine Threads |
STEP 11
Select the Newly Created Standard, Metric Fine Threads. The Hole Wizard Window will appear.Select the Hole Wizard Folder |
STEP 12
Select the Hole Wizard Holes Folder. The Tapped Hole Folder will appear now, Select the Tapped Hole Icon.Enabled Column – Sizes |
STEP 13
Select the Tapped Hole Icon and the Sizes Window will appear. Now, Uncheck/Turn Off all the Coarse threads under the “Enabled” column.Add New Row Column – Sizes |
STEP 14
Select the “Add New Row” Icon located to the Left of the Enabled Column. Now the Add New Row Window will appear.New Row Information Filled In – OK Button |
The Toolbox Additional Information Window will appear, just Select Ok.
Toolbox Additional Information Required Window – OK Button |
You will notice M5x.5 row added at the bottom of the screen.
Thread Data Window |
STEP 15
Select “Thread Data” from the Left Side Panel.Select the “Add New Row” icon, located next Enabled.
Add New Row Information Window – Thread Data |
Now, the Add New Row Information Window will appear.
STEP 16
Fill in the requested information for a New Thread; we will be adding the information for an M5x.5 thread.Some of the Information Names are not clear thus, below is an explanation what they mean. In the bracket is the information used for our thread. The information used in this instruction can be found in the Machinery’s Handbook.
Advance: Thread Pitch (.5)
Thread Minor Thread: Minor Diameter of an External Thread (4.272)
Thread Minor Thread Inside: Minor Diameter of an Internal Thread (4.599)
Fullsize: Hole Callout Display (M5x.5)
Select the OK button after all the information is filled in.
New Thread Data Added |
New Thread Data Information Filled Out |
The New Thread Data is added and displayed in the bottom row.
STEP 17
The process is now completed. Select the “X” (Close) located in the Top Right Corner of the screen. There will be a “Toolbox – Save Changes?” Window appear after selection. Select “Yes” and the Hole Wizard/Toolbox Window will Close.Toolbox – Save Changes? Window |
STEP 18
Now, we want to verify that the New M5x.5 Tapped Hole was correctly added to the Hole Wizard. We will create a new SolidWorks simple model to test our New Hole Wizard Tapped Hole.SolidWorks Test Model – Hole Wizard |
Hole Wizard Tapped Hole Information Selected |
There you have it, an M5x.5 Tapped Hole!
M5x.5 Tapped Hole |
M5x.5 Tapped Hole Callout – Drawing |
Congratulations, you have created a new Hole Wizard/Toolbox Standard.
Article by Ralph Wright, CSWP
0 Comments:
Post a Comment